Glass Insulator - AC & DC


SYGG's glass inaulators so far has the best shattering rate in the industry with its digitally control glass roughening manufacturering process. There are more than 30 millions of SYGG's glass insulators are in operation world wide. The SYGG's glass inulators passed type/design tests per ANSI C29-2B, CSA 411-1-16, and IEC 60383.


The voltage ratings up to:      1000kV  AC,  +-1100kV DC

The mechnical ratings up to:  840kN


SYGG Toughened Glass Insulator Catalog Numbering

SYGG Glass Insulator Catalog Numbering


Profiles and Types of SYGG Glass Insulators

SYGG Insulators Standard Profile

SYGGAnti-Fog

SYGGOpen/Aerodynamic

SYGGSpherical

SYGGOutrib

SYGGFull RTV Coating

SYGG Bottom RTV Coating

SYGGFor Grounding



Glass Insulator - AC & DC - Catalog


Per  CSA-411-1-16  Table 2

Download ASNI/CSA/SYGG/SEDIVER Cross Reference here


SYGG Cat. No.

CSA Type

Maximum nominal diameter, D, mm

Nominal spacing, S, mm

Minimum nominal creepage distance, mm

Electromechanical failing load, kN

Mechanical tension proof load, kN

Mechanical impact strength, N•m

Connecting hardware type

Sediver Cat. No.

U45C-140CS

CS-1

165

140

178

45

22

5

Clevis


U70C-146CS

CS-2

203

146

210

70

34

5.5

Clevis


U70B-146CS

CS-3

273

146

292

70

34

6

Ball & Socket

N70/146

U70C-146CS

CS-4

273

146

292

70

34

6

Clevis


U120B-146CS

CS-5

273

146

279

120

56

7

Ball & Socket

N12/146

U120C-146CS

CS-6

273

146

279

120

56

7

Clevis

CT12/146

U160B-146CS

CS-8

298

146

318

160

80

10

Ball & Socket

N160/146

U160B-170CS

CS-8A

298

170

318

160

80

10

Ball & Socket

N16/171

U45C-159CS

CS-9A

114

159

171

45

22

5

Clevis


U45B-159CS

CS-9B

133

159

171

45

22

5

Clevis


U160C-165CS

CS-10

298

165

270

160

80

10

Clevis


U220B-156CS

CS-11

311

156

381

220

112

10

Ball & Socket

N21/156

U220B-170CS

CS-11A

311

170

381

220

112

10

Ball & Socket

N21/171

U220C-178CS

CS-12

311

178

381

220

112

10

Clevis


U300B-195CS

CS-13

320

195

370

300

150

10

Ball & Socket

F300/195

U400B-205CS

CS-14

360

205

525

400

200

10

Ball & Socket

F400/205

U530B-240CS

CS-15

380

240

600

530

265

10

Ball & Socket



Per ANSI/NEMA C29.2 B-2013   Table 2


SYGG Cat. No.

ANSI Type

Connection Type

Leakage distance, inches (mm)

Spacing, inches (mm)

Shell diameter, inches (mm)

M&E strength, pounds (kN)

Impact strength, inch- pounds (N-m)

Tension proof, pounds (kN)

Low- frequency dry flashover, kV

Low- frequency wet flashover, kV

Critical impulse flashover, positive, kV

Critical impulse flashover, negative, kV

Low- frequency puncture voltage, kV

Low- frequency test voltage, kV

Maximum RIV at 1,000 kHz,uV

CSA Type

Sediver Cat no.

U70B-146A

52-3-L

B&S Type B

11-1/2(292)

5-3/4 (146)

10-3/4(273)

15000(67)

55 (6.0)

7500(33.5)

80

50

125

130

110

10

50

CS-3

N70/146

U100B-146A

52-3-H

B&S Type B

11-1/2(292)

5-3/4 (146)

10-3/4(273)

20000(89)

55 (6.0)

10000(44.5)

80

50

125

130

110

10

50


N100/146

U70C-146A

52-4-L

Clevis

11-1/2(292)

5-3/4 (146)

10-3/4(273)

15000(67)

55 (6.0)

7500(33.5)

80

50

125

130

110

10

50



U100C-146A

52-4-H

Clevis

11-1/2(292)

5-3/4 (146)

10-3/4(273)

20000(89)

55 (6.0)

10000(44.5)

80

50

125

130

110

10

50


CT100/146

U140B-120A

52-5-L

B&S Type J

11(279)

5-3/4 (146)

10-3/4(273)

25000(111)

60 (7.0)

12500(55.5)

80

50

125

130

110

10

50

CS-5

N12/146

U140B-146A

52-5-H

B&S Type J

11(279)

5-3/4 (146)

10-3/4(273)

3000(133)

60 (7.0)

15000(66.5)

80

50

125

130

110

10

50


N14/146

U120C-146A

52-6-L

Clevis

11(279)

5-3/4 (146)

10-3/4(273)

25000(111)

60 (7.0)

12500(55.5)

80

50

125

130

110

10

50

CS-6

CT12/146

U140C-146A

52-6-H

Clevis

11(279)

5-3/4 (146)

10-3/4(273)

30000(133)

60 (7.0)

15000(66.5)

80

50

125

130

110

10

50


CT14/146

U160B-146A

52-8-L

B&S Type K

11(279)

5-3/4 (146)

11-3/4(298)

36000(160)

90 (10)

18000(80)

80

50

125

130

110

10

50

CS-8(*1)

N160/146

U180B-146A

52-8-H

B&S Type K

11(279)

5-3/4 (146)

11-3/4(298)

40000(178)

90 (10)

20000(89)

80

50

125

130

110

10

50

CS-8A

N180/146

U160C-146A

52-10-L

Clevis

11(279)

6-1/2 (165)

11-3/4(298)

36000(160)

90 (10)

18000(80)

80

50

125


110

10

50



U180C-146A

52-10-H

Clevis

11(279)

6-1/2 (165)

11-3/4(298)

40000(178)

90 (10)

20000(89)

80

50

125

130

110

10

50



U230B-156A

52-11

B&S Type K

15(381)

6-1/8 (155.5)

12-1/4(311)

50000(222)

90 (10)

25000(111)

95

50

140

140

125

10

50

CS-11(*2)

N21/156

U230C-178A

52-12

Clevis

15(381)

7(178)

12-1/4(311)

50000(222)

90 (10)

25000(111)

100

50

140

140

125

10

50



Note *1.  CS-8  and 52-8-L has diferrent leakage distance ( 52-8-H:  279 mm   CS-8: 318 mm )

Note 21.  CS-1  and 52-11 has diferrent leakage distance ( 52-11:  155.5 mm   CS-11: 156 mm )


The 3rd Party Type/Design Test Reports per ANSI/IEEE/CSA, IEC

SYGG PowerTech Lab

SYGG EGU

SYGG VEIKI

SYGG CEPRI